2.8.5. Sensor of provision of a butterfly valveCheck
Disconnect a wire from a negative conclusion of the rechargeable battery and I will corrode from the air temperature sensor on an admission.
Remove the air filter assembled with the taking-away hose and disconnect the socket of the sensor of provision of a butterfly valve.
|
Fig. 2.277. Check of the sensor of provision of a butterfly valve: 1 – conclusion of basic tension; 2 – conclusion of output tension; 3 – weight conclusion
|
Using an ohmmeter, check resistance between conclusions according to the table (fig. 2.277) given below.
If the result of check does not meet standard, replace the sensor of provision of a butterfly valve.
NOTE
The difference of indications of an ohmmeter at completely open and completely closed butterfly valve has to be not less than 2 kOhm.
|
Connect the socket of the sensor of provision of a butterfly valve.
Connect a wire to a negative conclusion of the rechargeable battery.
Removal
Disconnect a wire from a negative conclusion of the rechargeable battery.
Remove a throttle branch pipe from an inlet collector.
Remove the sensor of provision of a butterfly valve from a throttle branch pipe.
Installation
|
Fig. 2.278. Installation of the sensor of provision of a butterfly valve
|
Install the sensor of provision of a butterfly valve 1 on a throttle branch pipe (fig. 2.278).
Install the sensor of provision of a butterfly valve on a throttle branch pipe so that its openings 3 were at some distance from openings under the screw of the sensor of provision of a butterfly valve 2, as shown in the left drawing, and turn the sensor of provision of a butterfly valve clockwise so that openings were combined by 3 (fig. 2.278).
Moment of an inhaling of the screw of the sensor of provision of a butterfly valve (a): 2,5 N · m.
Connect the socket to the sensor of provision of a butterfly valve.
Connect a wire to a negative conclusion the rechargeable battery.
|